Capillary Tube And Bulb Indicating Thermometer

Loading

  • Part Name
    CAPILLARY TUBE AND BULB INDICATING THERMOMETER
  • Federal Supply Class
    Pressure, Temperature, And Humidity Measuring And Controlling Instruments
  • NIIN
    014934710
  • Part Number
    ITR-45-24-A-030-15-0, MIL-T-19646, M19646-C124D430
  • National Stock Number
    6685-01-493-4710
  • Item Name Code
    7419
Specifications
  • SCALE TYPE
    DIAL
  • SCALE MEASUREMENT RANGE
    20.000 TO 240.000 DEG FAHRENHEIT
  • MATERIAL
    STEEL CORROSION RESISTING OVERALL
  • STYLE DESIGNATOR
    BULB W/O SOCKET
  • BULB TIP LENGTH
    6.000 INCHES NOMINAL
  • CASE DIAMETER
    5.375 INCHES NOMINAL
  • DIAL DIAMETER
    4.500 INCHES NOMINAL
  • POINTER/PEN TYPE AND QUANTITY
    1 INDICATING SINGLE
  • BULB TYPE
    PLAIN RIGID
  • BULB QUANTITY
    1
  • BULB STYLE
    PLAIN BULB
  • ACTIVE PORTION LENGTH
    6.000 INCHES NOMINAL
  • ACTIVE PORTION DIAMETER
    0.625 INCHES NOMINAL
  • BULB OVERALL LENGTH
    21.000 INCHES NOMINAL
  • EXTENSION NECK LENGTH
    15.000 INCHES NOMINAL
  • BULB CONNECTION TYPE
    UNION
  • FLEXIBLE TUBE LENGTH
    360.000 INCHES NOMINAL
  • ACTUATING MEDIUM
    LIQUID
  • SPEC/STD CONTROLLING DATA
  • MANUFACTURERS CODE
    81349
  • NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE
    MIL-T-19646
  • MANUFACTURERS CODE
    81349
  • DEFINITIVE GOVERNMENT SPEC/STD REFERENCE
    M19646-C124D430
Restrictions
  • Demilitarization Code
    A

    Items subject to the Export Administration Regulations (EAR) in parts 773-74 of Title 15, Code of Federal Regulations (CFR) (CCLI or EAR99) and determined by the DoD to present a low risk when released out of DoD control. No DEMIL, MUT or end use certificate is required. May require an export license from DOC.

  • Criticality Code
    X

    Does not have a nuclear hardened feature or other critical feature such as tolerance, fit restriction or application.

  • Hazardous Material Code
    P

    There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

  • Precious Metals Code (PMIC)
    A

    Item does not contain Precious Metal.

Request Quote

Click the + sign at the end of the row to add another row/part