Toggle Switch

Loading

  • Part Name
    TOGGLE SWITCH
  • Federal Supply Class
    Switches
  • NIIN
    010914635
  • Part Number
    537534-1, 68AT11-5
  • National Stock Number
    5930-01-091-4635
  • Item Name Code
    184
Specifications
  • NONPILE-UP CONTACT ARRANGEMENT
    8 POLE, DOUBLE THROW, ONE POSITION MOMENTARY, TWO POSITIONS MAINTAINED SINGLE SWITCH UNIT
  • MAXIMUM VOLTAGE RATING IN VOLTS
    115.0 AC AND
  • 28.0 DC
  • CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE
    7.000 AMPERES RESISTIVE DC AND
  • 4.000 AMPERES INDUCTIVE DC AND
  • 2.500 AMPERES LAMP DC AND
  • 4.000 AMPERES MOTOR DC AND
  • 7.000 AMPERES RESISTIVE AC AND
  • 7.000 AMPERES INDUCTIVE AC AND
  • 2.500 AMPERES LAMP AC AND
  • 3.300 AMPERES MOTOR AC
  • BODY STYLE
    BUSHING MOUNT
  • BUSHING LENGTH
    0.470 INCHES NOMINAL
  • BODY LENGTH
    1.170 INCHES MAXIMUM
  • BODY WIDTH
    1.100 INCHES MAXIMUM
  • BODY HEIGHT
    1.095 INCHES NOMINAL
  • OVERALL LENGTH
    1.170 INCHES MAXIMUM
  • OVERALL WIDTH
    1.100 INCHES MAXIMUM
  • OVERALL HEIGHT
    2.250 INCHES NOMINAL
  • ACTUATOR STYLE
    ROUND
  • ACTUATOR DIAMETER
    0.240 INCHES NOMINAL
  • ACTUATOR HEIGHT
    0.680 INCHES NOMINAL
  • ACTUATOR POSITION-ACTION RELATIONSHIP
    UP POSITION MAINTAINED AND
  • DOWN POSITION MOMENTARY AND
  • CENTER POSITION MAINTAINED
  • TERMINAL TYPE AND QUANTITY
    24 TAB, SOLDER LUG
  • INCLOSURE TYPE
    FULLY INCLOSED
  • MOUNTING METHOD
    THREADED BUSHING
  • THREAD SERIES DESIGNATOR
    UNS
  • NOMINAL THREAD SIZE
    0.469 INCHES
  • THREAD QUANTITY PER INCH
    32
Restrictions
  • Demilitarization Code
    A

    Items subject to the Export Administration Regulations (EAR) in parts 773-74 of Title 15, Code of Federal Regulations (CFR) (CCLI or EAR99) and determined by the DoD to present a low risk when released out of DoD control. No DEMIL, MUT or end use certificate is required. May require an export license from DOC.

  • Criticality Code
    X

    Does not have a nuclear hardened feature or other critical feature such as tolerance, fit restriction or application.

  • Hazardous Material Code
    P

    There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

  • Precious Metals Code (PMIC)
    U

    Precious Metal type is unknown.

Request Quote