myskyhawk

Rotary Switch Section

Loading

Myskyhawk

Myskyhawk

Myskyhawk

Myskyhawk

Myskyhawk
  • Part Name
    ROTARY SWITCH SECTION
  • Federal Supply Class
    Switches
  • NIIN
    000858093
  • Part Number
    217317-RK, 269-2297-00, 269-2297-000
  • National Stock Number
    5930-00-085-8093
  • Item Name Code
    15315

Myskyhawk

Myskyhawk

Myskyhawk

Specifications
  • III STYLE DESIGNATOR
    SWITCH SECTION, ROTARY
  • OVERALL HEIGHT
    1.859 INCHES MAXIMUM
  • OVERALL WIDTH
    1.734 INCHES MAXIMUM
  • BODY THICKNESS
    0.063 INCHES NOMINAL
  • SWITCH CONTACT BASIC DESIGN
    NONPILE-UP SYMMETRICAL
  • POLE QUANTITY
    1 SINGLE SECTION FRONT
  • 1 SINGLE SECTION REAR
  • THROW QUANTITY
    5 SINGLE SECTION FRONT
  • 5 SINGLE SECTION REAR
  • CONTACT SWITCHING ACTION
    MAKES BEFORE BREAKS SINGLE SECTION FRONT
  • MAKES BEFORE BREAKS SINGLE SECTION REAR
  • CONTACT VOLTAGE RATING IN VOLTS
    115.0 AC AT ALTITUDE
  • 28.0 DC AT SEA LEVEL
  • 28.0 DC AT ALTITUDE
  • 300.0 HIGHEST AC VOLTAGE RATING AT SEA LEVEL
  • 115.0 LOWEST AC VOLTAGE RATING AT SEA LEVEL
  • CONTACT LOAD CURRENT RATING
    100.0 MILLIAMPERES RESISTIVE LOAD AC AT ALTITUDE
  • 500.0 MILLIAMPERES RESISTIVE LOAD AND
  • 50.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL
  • 350.0 MILLIAMPERES RESISTIVE LOAD DC AT ALTITUDE
  • 50.0 MILLIAMPERES RESISTIVE LOAD HIGHEST AC VOLTAGE RATING AT SEA LEVEL
  • 250.0 MILLIAMPERES RESISTIVE LOAD LOWEST AC VOLTAGE RATING AT SEA LEVEL
  • TERMINAL TYPE
    TAB, SOLDER LUG
  • MOUNTING METHOD
    STRUT AND
  • UNTHREADED HOLE SINGLE MOUNTING FACILITY
  • UNTHREADED MOUNTING HOLE DIAMETER
    0.126 INCHES NOMINAL SINGLE MOUNTING FACILITY
  • MOUNTING FACILITY PATTERN
    TWO POSITION IN-LINE SINGLE MOUNTING FACILITY
  • DISTANCE BETWEEN MOUNTING FACILITY CENTERS
    1.362 INCHES NOMINAL SINGLE MOUNTING FACILITY
  • LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS
    1.562 INCHES NOMINAL SINGLE MOUNTING FACILITY
  • TEST DATA DOCUMENT
    81349-MIL-S-3786 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
  • III OPERATING TEMP RANGE
    -55.0 TO 85.0 DEG CELSIUS

Myskyhawk

Myskyhawk

Request Quote

Click the + sign at the end of the row to add another row/part