Electromagnetic Relay

Loading

  • Part Name
    ELECTROMAGNETIC RELAY
  • Federal Supply Class
    Relays And Solenoids
  • NIIN
    001649672
  • Part Number
    CK2C
  • National Stock Number
    5945-00-164-9672
  • Item Name Code
    32512
Specifications
  • NONPILE-UP MAIN CONTACT ARRANGEMENT
    3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
  • MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS
    115.0 AC AND
  • 28.0 DC
  • MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE
    10.0 AMPERES AC AND
  • 3.5 AMPERES DC RESISTIVE LOAD
  • COIL QUANTITY
    1
  • WINDING QUANTITY
    1
  • WINDING DC RESISTANCE RATING
    18.0 OHMS NOMINAL SINGLE WINDING
  • OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP
    6.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
  • TERMINAL TYPE AND QUANTITY
    8 PIN ALL FUNCTIONS
  • TIME DELAY
    0.01 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME
  • DUTY TYPE
    CONTINUOUS
  • ENVIRONMENTAL PROTECTION
    DUSTPROOF
  • OVERALL LENGTH
    1.714 INCHES MAXIMUM
  • OVERALL WIDTH
    1.175 INCHES NOMINAL
  • OVERALL HEIGHT
    0.515 INCHES NOMINAL
  • MOUNTING FACILITY TYPE AND QUANTITY
    2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
  • MOUNTING FACILITY PATTERN
    IN-LINE SINGLE MOUNTING FACILITY
  • CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
    1.446 INCHES NOMINAL SINGLE MOUNTING FACILITY
  • UNTHREADED MOUNTING HOLE DIAMETER
    0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY
Restrictions
  • Demilitarization Code
    A

    Items subject to the Export Administration Regulations (EAR) in parts 773-74 of Title 15, Code of Federal Regulations (CFR) (CCLI or EAR99) and determined by the DoD to present a low risk when released out of DoD control. No DEMIL, MUT or end use certificate is required. May require an export license from DOC.

  • Criticality Code
    X

    Does not have a nuclear hardened feature or other critical feature such as tolerance, fit restriction or application.

  • Hazardous Material Code
    N

    There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.

  • Precious Metals Code (PMIC)
    U

    Precious Metal type is unknown.