Power Autotransformer Transformer

Loading

  • Part Name
    POWER AUTOTRANSFORMER TRANSFORMER
  • Federal Supply Class
    Coils And Transformers
  • NIIN
    010914651
  • Part Number
    146
  • National Stock Number
    5950-01-091-4651
  • Item Name Code
    36166
Specifications
  • TERMINAL TYPE AND QUANTITY
    5 THREADED STUD
  • WINDING OPERATING VOLTAGE
    120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT
  • 0.00 AC VOLTS MINIMUM AND
  • 120.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT
  • WINDING OPERATING CURRENT
    30.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT
  • WINDING POWER RATING
    3.6 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE PRIMARY OUTPUT
  • FREQUENCY RATING
    50.0 HERTZ NOMINAL OR
  • 60.0 HERTZ NOMINAL SINGLE COMPONENT
  • ADJUSTMENT METHOD AND QUANTITY
    1 ADJUSTABLE CONTROL SINGLE COMPONENT
  • ADJUSTMENT DEVICE DRIVE TYPE
    SHAFT SINGLE COMPONENT
  • WINDING FUNCTION AND QUANTITY
    1 PRIMARY, VARIABLE AUTOTRANSFORMER TYPE SINGLE COMPONENT
  • INPUT-OUTPUT PHASE RELATIONSHIP
    SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • MOUNTING METHOD
    SLOT SINGLE GROUP
  • MOUNTING FACILITY QUANTITY
    4 SINGLE GROUP
  • MOUNTING SLOT WIDTH
    0.380 INCHES NOMINAL SINGLE GROUP
  • INCLOSURE TYPE
    FULLY INCLOSED
  • OVERALL LENGTH
    11.440 INCHES NOMINAL
  • OVERALL HEIGHT
    6.380 INCHES NOMINAL
  • OVERALL WIDTH
    9.560 INCHES NOMINAL
  • RELIABILITY INDICATOR
    NOT ESTABLISHED
Restrictions
  • Demilitarization Code
    A

    Items subject to the Export Administration Regulations (EAR) in parts 773-74 of Title 15, Code of Federal Regulations (CFR) (CCLI or EAR99) and determined by the DoD to present a low risk when released out of DoD control. No DEMIL, MUT or end use certificate is required. May require an export license from DOC.

  • Criticality Code
    X

    Does not have a nuclear hardened feature or other critical feature such as tolerance, fit restriction or application.

  • Hazardous Material Code
    P

    There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

  • Precious Metals Code (PMIC)
    U

    Precious Metal type is unknown.

Request Quote

Click the + sign at the end of the row to add another row/part