myskyhawk

Circuit Breaker

Loading

Myskyhawk

Myskyhawk

Myskyhawk

Myskyhawk

Myskyhawk
  • Part Name
    CIRCUIT BREAKER
  • Federal Supply Class
    Circuit Breakers
  • NIIN
    013189443
  • Part Number
    NJL631400MTO-ASF-1, NJL631400MT0, NJL632400MTO-AL 1
  • National Stock Number
    5925-01-318-9443
  • Item Name Code
    136

Myskyhawk

Myskyhawk

Myskyhawk

Specifications
  • POLE QUANTITY
    3
  • MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
    400.0 AMPERES AC AND
  • 400.0 AMPERES DC ALL LOCATIONS
  • CIRCUIT PROTECTION TYPE
    OVERCURRENT ALL LOCATIONS
  • TERMINAL TYPE AND QUANTITY
    6 COMPRESSION
  • OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
    600.0 AC AND
  • 250.0 DC ALL LOCATIONS
  • TRIP RELEASE METHOD
    THERMAL-MAGNETIC ALL LOCATIONS
  • TRIP RELEASE CHARACTERISTIC
    INSTANTANEOUS ALL LOCATIONS
  • RESET METHOD
    MANUAL
  • BODY STYLE
    MULTIPOLE-SINGLE ACTUATOR TYPE
  • CASE MATERIAL
    PLASTIC
  • MOUNTING FACILITY TYPE AND QUANTITY
    4 THREADED STUD
  • FREQUENCY IN HERTZ
    60.0 ALL LOCATIONS
  • MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
    150000.0 AC AND
  • 220000.0 DC ALL LOCATIONS
  • TRIP RELEASE AMBIENT TEMP RATING
    40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
  • ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
    125.0 ALL LOCATIONS
  • MAIN CONTACT TRIPPING MECHANISM TYPE
    TRIP FREE
  • BODY LENGTH
    10.120 INCHES NOMINAL
  • BODY WIDTH
    8.250 INCHES NOMINAL
  • BODY HEIGHT
    4.080 INCHES NOMINAL
  • CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
    9.120 INCHES NOMINAL
  • CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH
    1.880 INCHES NOMINAL
  • DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH
    7.250 INCHES NOMINAL
  • DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH
    1.220 INCHES NOMINAL
  • BOSS HEIGHT
    0.250 INCHES NOMINAL
  • THREAD SERIES DESIGNATOR
    UNC
  • NOMINAL THREAD SIZE
    0.500 INCHES
  • THREAD QUANTITY PER INCH
    13
  • MANUAL ACTUATOR TYPE AND QUANTITY
    1 TOGGLE
  • ACTUATOR FUNCTION
    TRIP-RESET
  • ACTUATOR POSITION DESIGNATION
    AT POLE TWO
  • AUXILIARY SWITCH FUNCTION AND QUANTITY
    1 ALARM
  • SWITCH LOCATION AND POSITION DESIGNATION
    INTERNAL AT POLE ONE
  • SWITCH CONTACT ARRANGEMENT
    SINGLE POLE, DOUBLE THROW
  • SWITCH CURRENT RATING AND TYPE IN AMPS
    5.0 AC
  • SWITCH VOLTAGE RATING AND TYPE IN VOLTS
    250.0 AC
  • SWITCH TERMINAL TYPE
    WIRE LEAD
  • INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED
    MOISTURE PROOF AND
  • FUNGUS PROOF
  • FEATURES PROVIDED
    ADJUSTABLE TRIP RELEASE
  • ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS
    3000.0 TO 4800.0 AC ALL LOCATIONS
  • III ARC QUENCHING METHOD
    MAGNETIC BLOWOUT
  • III STORAGE TYPE
    GENERAL PURPOSE WAREHOUSE
  • III FRAGILITY FACTOR
    MODERATELY RUGGED

Myskyhawk

Myskyhawk

Request Quote

Click the + sign at the end of the row to add another row/part

LET US EARN YOUR TRUST AND BECOME A PARTNER FOR LIFE