Paper Dielectric Fixed Capacitor

Loading

  • Part Name
    PAPER DIELECTRIC FIXED CAPACITOR
  • Federal Supply Class
    Capacitors
  • NIIN
    001647573
  • Part Number
    D161884A, D161884A, 441A, 441A, 441A, 441A, 441ACAPACIT0R, 441ACAPACIT0R
  • National Stock Number
    5910-00-164-7573
  • Item Name Code
    3
Specifications
  • III CAPACITANCE VALUE PER SECTION
    1.000 MICROFARADS SINGLE SECTION
  • TOLERANCE RANGE PER SECTION
    0.00 TO 0.25 MICROFARADS SINGLE SECTION
  • NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION
    180.0 AC-RMS SINGLE SECTION AND
  • 200.0 DC SINGLE SECTION
  • NONDERATED OPERATING TEMP
    -55.0 DEG CELSIUS MINIMUM AND
  • 85.0 DEG CELSIUS MAXIMUM
  • BODY STYLE
    W/THD MTG HOLE(S)/STUD(S) TERMINAL(S) ON ONE SURFACE
  • BODY LENGTH
    1.406 INCHES NOMINAL
  • BODY WIDTH
    0.469 INCHES NOMINAL
  • BODY HEIGHT
    3.438 INCHES NOMINAL
  • SCHEMATIC DIAGRAM DESIGNATOR
    NO COMMON OR GROUNDED ELECTRODE(S)
  • TERMINAL TYPE AND QUANTITY
    2 TAB, SOLDER LUG
  • CASE MATERIAL
    METAL
  • MOUNTING FACILITY TYPE AND QUANTITY
    2 THREADED MOUNTING STUDS
  • DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH
    1.000 INCHES NOMINAL
  • RELIABILITY INDICATOR
    NOT ESTABLISHED
  • TEST DATA DOCUMENT
    81349-MIL-C020/7 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Restrictions
  • Demilitarization Code
    A

    Items subject to the Export Administration Regulations (EAR) in parts 773-74 of Title 15, Code of Federal Regulations (CFR) (CCLI or EAR99) and determined by the DoD to present a low risk when released out of DoD control. No DEMIL, MUT or end use certificate is required. May require an export license from DOC.

  • Criticality Code
    X

    Does not have a nuclear hardened feature or other critical feature such as tolerance, fit restriction or application.

  • Hazardous Material Code
    P

    There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

  • Precious Metals Code (PMIC)
    U

    Precious Metal type is unknown.

Request Quote