Paper Dielectric Fixed Capacitor

Loading

  • Part Name
    PAPER DIELECTRIC FIXED CAPACITOR
  • Federal Supply Class
    Capacitors
  • NIIN
    001647525
  • Part Number
    CP70E1EJ104V, JANC25
  • National Stock Number
    5910-00-164-7525
  • Item Name Code
    3
Specifications
  • III CAPACITANCE VALUE PER SECTION
    0.100 MICROFARADS SINGLE SECTION
  • TOLERANCE RANGE PER SECTION
    -10.00 TO 20.00 PERCENT SINGLE SECTION
  • NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION
    2000.0 DC SINGLE SECTION
  • BODY STYLE
    W/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE
  • BODY LENGTH
    2.500 INCHES NOMINAL
  • BODY WIDTH
    1.188 INCHES NOMINAL
  • BODY HEIGHT
    2.500 INCHES NOMINAL
  • SCHEMATIC DIAGRAM DESIGNATOR
    NO COMMON OR GROUNDED ELECTRODE(S)
  • TERMINAL TYPE AND QUANTITY
    2 SOLDER STUD
  • TERMINAL HEIGHT FROM BODY
    1.750 INCHES NOMINAL
  • CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
    1.125 INCHES NOMINAL
  • CASE MATERIAL
    METAL
  • RELIABILITY INDICATOR
    NOT ESTABLISHED
  • FEATURES PROVIDED
    HERMETICALLY SEALED CASE
  • SPEC/STD CONTROLLING DATA
  • MANUFACTURERS CODE
    81350
  • DEFINITIVE GOVERNMENT SPEC/STD REFERENCE
    CP70E1EJ104V
  • MANUFACTURERS CODE
    81350
  • NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE
    JANC25
Restrictions
  • Demilitarization Code
    A

    Items subject to the Export Administration Regulations (EAR) in parts 773-74 of Title 15, Code of Federal Regulations (CFR) (CCLI or EAR99) and determined by the DoD to present a low risk when released out of DoD control. No DEMIL, MUT or end use certificate is required. May require an export license from DOC.

  • Criticality Code
    X

    Does not have a nuclear hardened feature or other critical feature such as tolerance, fit restriction or application.

  • Hazardous Material Code
    P

    There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

  • Precious Metals Code (PMIC)
    U

    Precious Metal type is unknown.

Request Quote