Ceramic Dielectric Fixed Capacitor

Loading

  • Part Name
    CERAMIC DIELECTRIC FIXED CAPACITOR
  • Federal Supply Class
    Capacitors
  • NIIN
    013383477
  • Part Number
    FD16X7R2A223M-T, RPE121978X7R223M100V, 0160-6516, 0160-6516
  • National Stock Number
    5910-01-338-3477
  • Item Name Code
    7
Specifications
  • CAPACITANCE VALUE PER SECTION
    0.022 MICROFARADS SINGLE SECTION
  • TOLERANCE RANGE PER SECTION
    -20.00 TO 20.00 PERCENT SINGLE SECTION
  • NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION
    100.0 DC SINGLE SECTION
  • VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE
    -15.0 TO 15.0 WITHOUT VOLTAGE APPLIED SINGLE SECTION
  • NONDERATED OPERATING TEMP
    -55.0 DEG CELSIUS MINIMUM AND
  • 125.0 DEG CELSIUS MAXIMUM
  • BODY STYLE
    W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
  • BODY LENGTH
    0.200 INCHES NOMINAL
  • BODY WIDTH
    0.200 INCHES NOMINAL
  • BODY HEIGHT
    0.125 INCHES NOMINAL
  • SCHEMATIC DIAGRAM DESIGNATOR
    NO COMMON OR GROUNDED ELECTRODE(S)
  • TERMINAL TYPE AND QUANTITY
    2 UNINSULATED WIRE LEAD
  • TERMINAL LENGTH
    0.500 INCHES NOMINAL
  • TERMINAL DIAMETER
    0.016 INCHES NOMINAL
  • CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
    0.100 INCHES NOMINAL
  • CASE MATERIAL
    PLASTIC
  • RELIABILITY INDICATOR
    NOT ESTABLISHED
  • SPECIFICATION/STANDARD DATA
    28480-0160-6516 MANUFACTURERS SPECIFICATION CONTROL
  • III TERMINAL SURFACE TREATMENT
    SOLDER
  • III END ITEM IDENTIFICATION
    6625-01-224-4440 NETWORK ANALYZE
Restrictions
  • Demilitarization Code
    A

    Items subject to the Export Administration Regulations (EAR) in parts 773-74 of Title 15, Code of Federal Regulations (CFR) (CCLI or EAR99) and determined by the DoD to present a low risk when released out of DoD control. No DEMIL, MUT or end use certificate is required. May require an export license from DOC.

  • Criticality Code
    X

    Does not have a nuclear hardened feature or other critical feature such as tolerance, fit restriction or application.

  • Hazardous Material Code
    P

    There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

  • Precious Metals Code (PMIC)
    A

    Item does not contain Precious Metal.

Request Quote