Electrical Resolver
Federal Supply Class | Synchros and Resolvers |
National Stock Number | 5990-00-146-3532 |
Item Name Code | 22966 |
Part Numbers | CM4103414, 725848-1 |
Serial Number | 001463532 |
Specifications
BODY SIZE | 8 |
ROTOR INPUT VOLTAGE RATING IN VOLTS | 6.3640 MINIMUM AND |
7.7780 MAXIMUM | |
ROTOR INPUT CURRENT RATING | 4.0 MILLIAMPERES NOMINAL |
ROTOR INPUT ELECTRICAL POWER RATING | 170.0 MILLIWATTS NOMINAL |
FREQUENCY IN HERTZ | 1287.0 MINIMUM AND |
1313.0 MAXIMUM | |
ZRO RESISTANCE IN OHMS | 302.10 MINIMUM AND |
333.90 MAXIMUM | |
PLUS J ZRO REACTANCE IN OHMS | 1496.00 MINIMUM AND |
2024.00 MAXIMUM | |
ZSO RESISTANCE IN OHMS | 57.80 MINIMUM AND |
78.20 MAXIMUM | |
PLUS J ZSO REACTANCE IN OHMS | 352.05 MINIMUM AND |
474.95 MAXIMUM | |
ROTOR DC RESISTANCE IN OHMS | 102.00 MINIMUM AND |
138.00 MAXIMUM | |
STATOR DC RESISTANCE IN OHMS | 19.30 MINIMUM AND |
26.10 MAXIMUM | |
TRANSFORMATION RATIO | 0.323 STATOR TO ROTOR MINIMUM AND |
0.601 STATOR TO ROTOR MAXIMUM | |
PHASE SHIFT ANGLE IN DEG | 3.200 INPUT TO OUTPUT MINIMUM AND |
4.800 INPUT TO OUTPUT MAXIMUM | |
MAXIMUM TEMP RISE | 20.0 DEG CELSIUS |
MAXIMUM TOTAL NULL VOLTAGE OUTPUT IN MILLIVOLTS PER VOLT | 10.00 |
ACTUATOR FRICTION TORQUE AT MINUS 55 DEG CELSIUS | 0.13 INCH-OUNCES MAXIMUM |
BODY STYLE | STANDARD ROUND A |
OVERALL LENGTH | 0.8750 INCHES MINIMUM AND |
1.7310 INCHES MAXIMUM | |
SHAFT TYPE | ROUND, SLOTTED SINGLE SHAFT |
SHAFT DIAMETER | 0.1195 INCHES MINIMUM FRONT SHAFT |
0.1200 INCHES MAXIMUM REAR SHAFT | |
SHAFT LENGTH | 0.3660 INCHES MINIMUM FRONT SHAFT |
0.4900 INCHES MAXIMUM REAR SHAFT | |
SHAFT SLOT DEPTH | 0.0300 INCHES NOMINAL SINGLE SHAFT |
SHAFT SLOT WIDTH | 0.0250 INCHES NOMINAL SINGLE SHAFT |
TERMINAL TYPE AND QUANTITY | 8 WIRE LEAD |
TERMINAL LOCATION | REAR |
SPEC/STD CONTROLLING DATA | |
MANUFACTURERS CODE | 96214 |
MFR SOURCE CONTROLLING REFERENCE | 725848-1 |
Restrictions
Demilitarization Code | Q | Commerce Control List Items (CCLI) - MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL Intergrity Code. (IC) '3' and MUT is not required when the DEMIL IS is '6'. |
Criticality Code | X | Does not have a nuclear hardened feature or other critical feature such as tolerance, fit restriction or application. |
Hazardous Materials Code | N | There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. |
Precious Metals Code (PMIC) | U | Precious Metal type is unknown. |